Преглед изворни кода

去掉voltage的一些调试,event_record已经处理了

Signed-off-by: huhui <huhui@sharkgulf.com>
huhui пре 4 година
родитељ
комит
976b9a5361
1 измењених фајлова са 1 додато и 13 уклоњено
  1. 1 13
      Application/app/sox/health.c

+ 1 - 13
Application/app/sox/health.c

@@ -60,9 +60,6 @@ static debounce_timer_t _load_detect_timer = {.max_count = 100, .interval = 10,
 static debounce_timer_t _charger_detect_timer = {.max_count = 500, .interval = 10, ._timer.handler = charger_detect_handler};
 static shark_timer_t _clear_short_current_timer = {.handler = clear_short_current_handler};
 static error_counts_t error_counts;
-static u16 discharger_lower_cell_voltage = 0;
-static u16 discharger_lower_voltage = 0;
-static u16 charger_over_cell_voltage = 0;
 
 void health_init(void){
 	/* 5238如果有异常情况,比如短路,负载移除,通过这个handler上报 */
@@ -80,8 +77,7 @@ void health_log(void){
 	health_debug("hard short:%d\n", error_counts.hard_current_short);
 	health_debug("work temp: %d\n", _health.is_work_temp_normal);
 	health_debug("aux_short: %d, %d\n", error_counts.aux_short, error_counts.aux_real_short);
-	health_debug("lower voltage: %d, %d, %d, %d\n", discharger_lower_cell_voltage, discharger_lower_voltage, error_counts.cell_under_voltage, error_counts.pack_under_voltage);
-	health_debug("over voltage: %d\n", charger_over_cell_voltage);
+	health_debug("lower voltage: %d, %d\n", error_counts.cell_under_voltage, error_counts.pack_under_voltage);
 	health_debug("uart error %d, %d, %d\n", error_counts.uart_crc_error, error_counts.uart_len_error, error_counts.uart_dir_error);
 	health_debug("Temp abnormal: %d,%d,%d,%d\n", error_counts.discharger_high_temp, error_counts.charger_high_temp, error_counts.discharger_lower_temp, error_counts.charger_lower_temp);
 }
@@ -273,10 +269,7 @@ void check_voltage_state(void) {
 	static uint16_t _charging = 0xFFFF;
 	if (_charging != bms_state_get()->charging) {
 		if (bms_state_get()->charging) {
-			charger_over_cell_voltage = 0;
 		}else {
-			discharger_lower_cell_voltage = 0;
-			discharger_lower_voltage = 0;
 			error_counts.cell_under_voltage = 0;
 		}
 		_charging = bms_state_get()->charging;
@@ -290,7 +283,6 @@ void check_voltage_state(void) {
 			if (judge_debounce(!_health.sigle_cell_over_voltage, &_sigle_cell_charger_max_vol)){
 				_health.sigle_cell_over_voltage = 1;
 				push_event(Cell_Over_Vol, bms_state_get()->cell_max_vol);
-				charger_over_cell_voltage = bms_state_get()->cell_max_vol;
 				sys_debug("sigle cell %d\n", bms_state_get()->cell_max_vol);
 			}
 		}else if ((bms_state_get()->cell_max_vol < SIGLE_CELL_MAX_CHARGER_VOLTAGE)){
@@ -309,7 +301,6 @@ void check_voltage_state(void) {
 				push_event(Cell_Under_Vol, bms_state_get()->cell_min_vol);
 				_single_low_judge_current(true);
 				error_counts.cell_under_voltage++;
-				discharger_lower_cell_voltage = bms_state_get()->cell_min_vol;
 			}
 		}else if ((bms_state_get()->cell_min_vol >= min_discharger_cell_recovery_vol[_health.is_work_temp_normal])){
 			_single_low_judge_current(false);
@@ -324,7 +315,6 @@ void check_voltage_state(void) {
 				push_event(Pack_Under_Vol, bms_state_get()->pack_voltage);
 				_pack_low_judge_current(true);
 				error_counts.pack_under_voltage++;
-				discharger_lower_voltage = bms_state_get()->pack_voltage;
 			}
 		}else if (bms_state_get()->pack_voltage >= min_discharger_recovery_vol[_health.is_work_temp_normal]){
 			_pack_low_judge_current(false);
@@ -336,7 +326,6 @@ void check_voltage_state(void) {
 		if ((bms_state_get()->cell_min_vol <= min_discharger_power_cell_vol[_health.is_work_temp_normal])){
 			if (judge_debounce(!_health.discharger_cell_shutpower_voltage, &_shut_discharger_cell_lower_voltage)){
 				_health.discharger_cell_shutpower_voltage = 1;
-				discharger_lower_cell_voltage = bms_state_get()->cell_min_vol;
 			}
 		}else if ((bms_state_get()->cell_min_vol >= min_discharger_power_recovery_cell_vol[_health.is_work_temp_normal])){
 			if (judge_debounce(_health.discharger_cell_shutpower_voltage, &_shut_discharger_cell_lower_voltage)){
@@ -346,7 +335,6 @@ void check_voltage_state(void) {
 		if ((bms_state_get()->pack_voltage <= min_discharger_power_vol[_health.is_work_temp_normal])){
 			if (judge_debounce(!_health.discharger_shutpower_voltage, &_shut_discharger_lower_voltage)){
 				_health.discharger_shutpower_voltage = 1;
-				discharger_lower_voltage = bms_state_get()->pack_voltage;
 			}
 		}else if ((bms_state_get()->pack_voltage >= min_discharger_power_recovery_vol[_health.is_work_temp_normal])){
 			if (judge_debounce(_health.discharger_shutpower_voltage, &_shut_discharger_lower_voltage)){